How deep
is the mark?
A small surface depression can be hard to judge by eye. This gauge turns it into a depth reading.
Find sound metal. Then find the low point.
The gauge compares the bottom of a local depression with the nearby surface. Its reference edge must sit on sound metal outside the defect while the measuring tip reaches the deepest point. The tables engraved on the body are quick references, not additional measurements.
Same gauge. Different surface.
Corrosion pit
- Place the gauge lengthwise along the pipe axis.
- Seat the reference edge on sound surfaces on both sides of the pit.
- Lower the arm until its tip reaches the deepest point.
- Hold the reference edge steady and read the depth with the tip in contact.
- Check several locations and record the maximum depth.
Across a curved pipe, the reference edge may sit unevenly. Follow the pipe axis; use a suitable straight reference bar if the surrounding surface is uneven.
Weld undercut
- Seat the reference edge on sound base metal beside the weld.
- Position the tip directly over the groove at the weld toe.
- Lower the arm until the tip touches the deepest point.
- Keep the edge seated and read the depth while tip contact is maintained.
- Repeat along the weld and record the maximum depth.
This scene photo identifies the groove. Use the gauge and the manual steps for an actual measurement.
From a mark to a recorded depth.
Localized corrosion
Find sound metal around the pit before measuring its lowest point.
Undercut beside a weld
Reference the adjacent base metal, then trace the deepest part of the groove.
Record the maximum
Measure more than one spot and retain the largest depth for review.
A number is a start.
The limit comes next.